- 2,000 VA / 1,400 Watt
- Tower
- Pure Sine Wave Clean Output To Operate And Maximize The Life Of Even The Most Sensitive Electronics
- Online (Double Conversion) - Highest Level Of Protection Available - Battery Power Always Engaged, No Switching Delay
- Accepts Generator Power (Direct or On Automatic Transfer Switch)
- Constant Voltage Regulation
- Constant Frequency Regulation
- Factory Warranty: 3 Years On Electronics And 1 Year Warranty On Batteries
- Optional Extended Warranty: 6 Years On Electronics And 3 Year Warranty On Batteries
- Heavy Duty Industrial Grade For Constant Use
- For Use With Ultrasound Machines
- 0.7 Power Factor
- 6 Batteries, 12 Volt, 7.2 Amp Hour Rating Each
- 12 Battery & Surge Protected Outlets
- NEMA 5-20R Input
- Estimated Run Time Based On Battery Configuration:
- 15 Minutes 14 Seconds UPS Only
- 45 Minutes 41 Seconds UPS Plus 1 Easy Connect Battery Cabinet
- 1 Hour 16 Minutes 08 Seconds UPS Plus 2 Easy Connect Battery Cabinets
- For Use With GE (General Electric) Voluson E6 Ultrasound Machine
- BBP-2000-PSW-ONL-LCD-VOLUSON-E6
- UL Listed, Company Reference E128840
- Includes UPSMON Plus For Windows Monitoring & Configuration Software: Download Here
- Add A Power Failure Cellular Text/SMS Alert Module
- Free Shipping/Freight Within The United States Or To U.S. Based Freight Forwarder Specified Location (List U.S. Based Location Specified By Forwarder In Shipping Address For International Orders)
*High Amperage Outlet Required To Provide Enough Power To The UPS To Recharge The Batteries And Continue Operating The Attached Electronics Immediately Following A Power Outage
How The University of Nevada, Reno Keeps Its Lab Running When The Power Fails
How Providence Medical Center Gets Excellent Lab Results Every Time
How Hematology Oncology Consultants Protects Its Life Saving Refrigerated Drugs
The Uninterruptible Power Supply (UPS) Inverter Capacity XXXX VA / XXXX Watts Determines How Many Watts Can Be Used From The UPS (How Large Of An Electrical Load). This Stays Constant Even If Extra Batteries Are Added. For Example, A 600 Watt UPS Can Run 10x 60 Watt Light Bulbs.
Extra Batteries Or External Battery Packs/Cabinets Increase Run Time (The Time Electronics Can Be Run On Battery Power). Extra Batteries Do Not Increase The Inverter Capacity (How Many Watts Can Be Used From The UPS). For Example, A 600 Watt UPS Can Still Only Run 10x 60 Watt Light Bulbs, But With Extra Batteries, It Can Run Those Light Bulbs Much Longer.
Get an estimation of how long your electronics will run on backup battery power with this unit during a power outage. Write down the Power Factor, Number of Batteries, Voltage of Batteries, and Amp Hour Rating from above, then click here to go to our uninterruptible power supply (UPS) backup run time calculator.