BBP-ADV-33-20K Battery Backup Power 120/208Y 3 Phase 20KVA 20KW Uninterrupted Uninterruptible Power Supply
BBP-ADV-33-20K Battery Backup Power 120/208Y 3 Phase 20KVA 20KW Uninterrupted Uninterruptible Power Supply With One External Battery Cabinet
BBP-ADV-33-20K Battery Backup Power 120/208Y 3 Phase 20KVA 20KW Uninterrupted Uninterruptible Power Supply With Two External Battery Cabinets
BBP-ADV-33-20K Battery Backup Power 120/208Y 3 Phase 20KVA 20KW Uninterrupted Uninterruptible Power Supply With Three External Battery Cabinets
BBP-ADV-33-20K Battery Backup Power 120/208Y 3 Phase 20KVA 20KW Uninterrupted Uninterruptible Power Supply With Four External Battery Cabinets
BBP-ADV-33-20K Battery Backup Power 120/208Y 3 Phase 20KVA 20KW Uninterrupted Uninterruptible Power Supply With Five External Battery Cabinets
BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Multiple Two Extended Backup Time External Battery Packs Connected For Long Duration Battery Backup Without Generator Back View Anderson Power Pole Connectors
BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Multiple Two Extended Backup Time External Battery Packs Connected For Long Duration Battery Backup Without Generator
BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Extended Backup Time External Battery Pack Connected Front Top View
BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Extended Backup Time External Battery Pack Connected
BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Multiple Two Extended Backup Time External Battery Packs Connected For Long Duration Battery Backup Without Generator Front View
BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Extended Backup Time External Battery Pack Connected Top Down Connection View
BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Multiple Two Extended Backup Time External Battery Packs Connected For Long Duration Battery Backup Without Generator Connected To Fused Disconnect Switch For Critical Loads
BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Extended Backup Time External Battery Pack Connected Top View Of LCD In Backup Power Double Conversion Online
BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Extended Backup Time External Battery Pack Connected Side View
BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Extended Backup Time External Battery Pack Connected Front View
BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Multiple Extended Backup Time External Battery Packs Connected Through Wall For Long Duration Battery Backup Without Generator Side By Side Hours Backup Days Backup Weeks Backup With Wrap Around Maintenance Bypass Switch On Wall Make Before Break Wall Pass Through
BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Multiple Extended Backup Time External Battery Packs Connected Through Wall For Long Duration Battery Backup Without Generator Side By Side Hours Backup Days Backup Weeks Backup With Wrap Around Maintenance Bypass Switch On Wall Make Before Break Front View Conduit
BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Multiple Extended Backup Time External Battery Packs Connected Through Wall For Long Duration Battery Backup Without Generator Side By Side Hours Backup Days Backup Weeks Backup With Wrap Around Maintenance Bypass Switch On Wall Make Before Break Electrical Panels Closed
BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Multiple Extended Backup Time External Battery Packs Connected Through Wall For Long Duration Battery Backup Without Generator Side By Side Hours Backup Days Backup Weeks Backup With Wrap Around Maintenance Bypass Switch On Wall Make Before Break And Transformer
BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Multiple Extended Backup Time External Battery Packs Connected Through Wall For Long Duration Battery Backup Without Generator Side By Side Hours Backup Days Backup Weeks Backup With Wrap Around Maintenance Bypass Switch On Wall Make Before Break
BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Multiple Five Extended Backup Time External Battery Packs Connected For Long Duration Battery Backup Without Generator Side By Side Hours Backup Days Backup Weeks Backup Front View
BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Multiple Five Extended Backup Time External Battery Packs Connected For Long Duration Battery Backup Without Generator Side By Side Hours Backup Days Backup Weeks Backup
  • Load image into Gallery viewer, BBP-ADV-33-20K Battery Backup Power 120/208Y 3 Phase 20KVA 20KW Uninterrupted Uninterruptible Power Supply
  • Load image into Gallery viewer, BBP-ADV-33-20K Battery Backup Power 120/208Y 3 Phase 20KVA 20KW Uninterrupted Uninterruptible Power Supply With One External Battery Cabinet
  • Load image into Gallery viewer, BBP-ADV-33-20K Battery Backup Power 120/208Y 3 Phase 20KVA 20KW Uninterrupted Uninterruptible Power Supply With Two External Battery Cabinets
  • Load image into Gallery viewer, BBP-ADV-33-20K Battery Backup Power 120/208Y 3 Phase 20KVA 20KW Uninterrupted Uninterruptible Power Supply With Three External Battery Cabinets
  • Load image into Gallery viewer, BBP-ADV-33-20K Battery Backup Power 120/208Y 3 Phase 20KVA 20KW Uninterrupted Uninterruptible Power Supply With Four External Battery Cabinets
  • Load image into Gallery viewer, BBP-ADV-33-20K Battery Backup Power 120/208Y 3 Phase 20KVA 20KW Uninterrupted Uninterruptible Power Supply With Five External Battery Cabinets
  • Load image into Gallery viewer, BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Multiple Two Extended Backup Time External Battery Packs Connected For Long Duration Battery Backup Without Generator Back View Anderson Power Pole Connectors
  • Load image into Gallery viewer, BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Multiple Two Extended Backup Time External Battery Packs Connected For Long Duration Battery Backup Without Generator
  • Load image into Gallery viewer, BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Extended Backup Time External Battery Pack Connected Front Top View
  • Load image into Gallery viewer, BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Extended Backup Time External Battery Pack Connected
  • Load image into Gallery viewer, BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Multiple Two Extended Backup Time External Battery Packs Connected For Long Duration Battery Backup Without Generator Front View
  • Load image into Gallery viewer, BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Extended Backup Time External Battery Pack Connected Top Down Connection View
  • Load image into Gallery viewer, BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Multiple Two Extended Backup Time External Battery Packs Connected For Long Duration Battery Backup Without Generator Connected To Fused Disconnect Switch For Critical Loads
  • Load image into Gallery viewer, BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Extended Backup Time External Battery Pack Connected Top View Of LCD In Backup Power Double Conversion Online
  • Load image into Gallery viewer, BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Extended Backup Time External Battery Pack Connected Side View
  • Load image into Gallery viewer, BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Extended Backup Time External Battery Pack Connected Front View
  • Load image into Gallery viewer, BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Multiple Extended Backup Time External Battery Packs Connected Through Wall For Long Duration Battery Backup Without Generator Side By Side Hours Backup Days Backup Weeks Backup With Wrap Around Maintenance Bypass Switch On Wall Make Before Break Wall Pass Through
  • Load image into Gallery viewer, BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Multiple Extended Backup Time External Battery Packs Connected Through Wall For Long Duration Battery Backup Without Generator Side By Side Hours Backup Days Backup Weeks Backup With Wrap Around Maintenance Bypass Switch On Wall Make Before Break Front View Conduit
  • Load image into Gallery viewer, BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Multiple Extended Backup Time External Battery Packs Connected Through Wall For Long Duration Battery Backup Without Generator Side By Side Hours Backup Days Backup Weeks Backup With Wrap Around Maintenance Bypass Switch On Wall Make Before Break Electrical Panels Closed
  • Load image into Gallery viewer, BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Multiple Extended Backup Time External Battery Packs Connected Through Wall For Long Duration Battery Backup Without Generator Side By Side Hours Backup Days Backup Weeks Backup With Wrap Around Maintenance Bypass Switch On Wall Make Before Break And Transformer
  • Load image into Gallery viewer, BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Multiple Extended Backup Time External Battery Packs Connected Through Wall For Long Duration Battery Backup Without Generator Side By Side Hours Backup Days Backup Weeks Backup With Wrap Around Maintenance Bypass Switch On Wall Make Before Break
  • Load image into Gallery viewer, BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Multiple Five Extended Backup Time External Battery Packs Connected For Long Duration Battery Backup Without Generator Side By Side Hours Backup Days Backup Weeks Backup Front View
  • Load image into Gallery viewer, BBP-ADV 3 Phase 120/208Y UPS 15KVA 20KVA With Multiple Five Extended Backup Time External Battery Packs Connected For Long Duration Battery Backup Without Generator Side By Side Hours Backup Days Backup Weeks Backup

20 kVA / 20 kW 3 Phase Power Conditioner, Voltage Regulator, & Battery Backup UPS (TAA Compliant)

Regular price
$ 17,999.99
Sale price
$ 17,999.99
Regular price
Sold out
Unit price
per 

UPS User Guide:
BBP-ADV-33 10K-40K 3 Phase UPS User And Installation Guide

Optional Network Card User Guide:
SNMP/Network Card User Guide For BBP-ADV-33 10KVA-40KVA 3 Phase UPS

Optional External Battery Cabinet User/Installation Guide: 
BBP-ADV-33 10KVA, 15KVA, & 20KVA Optional External Battery Cabinet User And Installation Guide

Spec Sheet/Cut Sheet:
BBP-ADV-33 10K-40K 3 Phase UPS Model Specifications

4 Tier Power Protection System – Surge Protection, Real Time Power Conditioning With Voltage Regulation, Pure Sine Wave Output, & Always On Double Conversion Backup Power Technology (Phase Locked To Utility Power Allowing Seamless Transition To Backup Power).

Do you need a PDF quote or a custom emergency backup solution? Email us at engineering@batterybackuppower.com

Multiple Backup Time Options:
Model Number: Description (Under Battery Options Drop Down): Approximate Backup Time At Full Load:
BBP-ADV-33-20K UPS With Internal Batteries Only (60 Batteries, 12 Volts, 9 Amp Hours Each) 6.48 KWH 9 Minutes
BBP-ADV-33-20K-WEBP UPS Plus 1 Extra External Battery Pack (140 Batteries, 12 Volts, 9 Amp Hours Each) 15.12 KWH 22 Minutes
BBP-ADV-33-20K-W2EBP UPS Plus 2 Extra External Battery Packs (220 Batteries, 12 Volts, 9 Amp Hours Each) 23.76 KWH 34 Minutes
BBP-ADV-33-20K-W3EBP UPS Plus 3 Extra External Battery Packs (300 Batteries, 12 Volts, 9 Amp Hours Each) 32.40 KWH 47 Minutes
BBP-ADV-33-20K-W4EBP UPS Plus 4 Extra External Battery Packs (380 Batteries, 12 Volts, 9 Amp Hours Each) 41.04 KWH 1 Hour 0 Minutes
BBP-ADV-33-20K-W5EBP UPS Plus 5 Extra External Battery Packs (460 Batteries, 12 Volts, 9 Amp Hours Each) 49.68 KWH 1 Hour 13 Minutes

  • Model: BBP-ADV-33-20K
  • 20000 VA (20 kVA) / 20000 Watt (20 kW) 
  • 3 Phase
  • Tower
  • Pure Sine Wave Clean Output To Operate And Maximize The Life Of Even The Most Sensitive Electronics
  • Online (Double Conversion) - Highest Level Of Protection Available - Battery Power Always Engaged, No Switching Delay
  • Accepts Generator Power (Direct or On Automatic Transfer Switch)
  • Constant Voltage Regulation
  • Constant Frequency Regulation
  • Factory Warranty: 3 Years On Electronics And 1 Year Warranty On Batteries 
  • Optional Extended Warranty: 6 Years On Electronics And 3 Year Warranty On Batteries
  • Heavy Duty Industrial Grade For Constant Use
  • For Use With Laboratory Instruments
  • For Use With Medical Devices
  • For Use With Hospital Equipment
  • For Use With Sensitive IT Equipment
  • 1.0 Power Factor (Unity Power Factor)
  • UL Listed
  • Management And Monitoring Software Included
  • Battery Configuration:
    • Built In 60x 12 Volt 9 Amp Hour Batteries
      • 9 Minutes (Full Load)
      • 18 Minutes (Half Load)
    • Add 1 Or More External Battery Cabinets To Extend Backup Time
    • Input:
      • 138~270 VAC 3 Phase @ 50% Load
      • 173~253 VAC 3 Phase @ 100% Load
    • Output:
      • 208/220 VAC 3 Phase
    • Full Load Estimated Run Time On Battery Power:
      • 9 Minutes With Internal Batteries
      • Contact Us For Additional Battery Cabinet Configurations
    • Operating Temperature Rating: 0C ~ +40C
    • Humidity: <95% And Non-Condensing
    • Dimensions D X W X H: 850mm X 410mm X 977mm (33.5 inches X 16.15 inches X 38.5 inches) 
    • Net Weight: 271 Kgs. (596 lbs.)

    How To Install Setup Wire A 3 Phase UPS

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)