Battery Backup Uninterruptible Power Supply (UPS) And Power Conditioner For Thermo Fisher Scientific / Applied Biosystems 7900HT Fast Real-Time PCR System

$ 4,799.99

The online (double conversion) pure sine wave lab safety battery backup uninterruptible power supply (UPS) and power conditioner with surge protector automatically provides defense against power problems that may impact the performance of the Thermo Fisher Scientific / Applied Biosystems 7900HT Fast Real-Time PCR System. Give your lab instruments longer life while protecting them from harmful dirty power problems that may otherwise damage or degrade their performance. Much more than a battery in a box, every Battery Backup Power, Inc. system doubles as a power conditioner, actively correcting voltage issues left unresolved by the power company or created by other power hungry electronics in your lab environment (laser printers, HVAC systems, refrigeration equipment, etc.).

Complete 5 Tier Laboratory Power Protection System (LPS/LPPS) – Surge Protection, Real Time Power Conditioning With Voltage Regulation, Heavy Duty Isolation Transformer, Pure Sine Wave Output, & Always On Double Conversion Backup Power Technology.

This is a plug and play system. An existing or electrician pre-wired 208 Volt, NEMA L6-20R (Receptacle) on a 20 amp breaker in your laboratory is all you need. Rolling casters allow you to easily move the entire unit from room to room for use wherever there is a 208 Volt, NEMA L6-20R (Receptacle) available. 

Do you need a PDF quote or a custom emergency backup solution? Email us at engineering@batterybackuppower.com

  • 3,000 VA (3 kVA) / 2,100 Watt (2.1 kW) Maximum Capacity
  • Built In Isolation Transformer To Suppress Electrical Noise For Sensitive Devices As Well As Protect Users From Faulty Equipment
  • Tower
  • Pure Sine Wave Clean Output To Operate And Maximize The Life Of Even The Most Sensitive Electronics
  • Online (Double Conversion) - Highest Level Of Protection Available - Battery Power Always Engaged, No Switching Delay
  • Accepts Generator Power (Direct or On Automatic Transfer Switch)
  • Constant Voltage Regulation
  • Constant Frequency Regulation
  • Factory Warranty: 3 Years On Electronics And Batteries
  • Optional Extended Warranty: 5 Years On Electronics and Batteries 
  • Heavy Duty Industrial Grade For Constant Use
  • For Use With Laboratory Instruments
  • 0.7 Power Factor
  • Internal Battery Pack With 12 Volt 7.0 Amp Hour Rated Batteries
  • INPUT: NEMA L6-20P (Plug), 208 Volt Single Phase, 20 Amp Breaker Required
    • Uses Existing or Electrician Pre-Wired NEMA L6-20R (Receptacle)  
  • OUTPUT: NEMA L6-20R (Receptacle), 208 Volt Single Phase
    • Full Load (2,100 Watts) Estimated Run Time On Battery Power:
      • 9 Minutes 24 Seconds UPS
        • 8x 12 Volt 7 Amp Hour Batteries
      • 28 Minutes 13 Seconds UPS + 1 Extended Run Time Battery Cabinet
        • 24x 12 Volt 7 Amp Hour Batteries
      • 47 Minutes 02 Seconds UPS + 2 Extended Run Time Battery Cabinets
        • 40x 12 Volt 7 Amp Hour Batteries
      • 65 Minutes 51 Seconds UPS + 3 Extended Run Time Battery Cabinets
        • 56x 12 Volt 7 Amp Hour Batteries
      • 84 Minutes 40 Seconds UPS + 4 Extended Run Time Battery Cabinets
        • 72x 12 Volt 7 Amp Hour Batteries
      • 103 Minutes 29 Seconds UPS + 5 Extended Run Time Battery Cabinets
        • 88x 12 Volt 7 Amp Hour Batteries
    • Half Load (1,050 Watts) Estimated Run Time On Battery Power:
      • 18 Minutes 49 Seconds UPS
        • 8x 12 Volt 7 Amp Hour Batteries
      • 56 Minutes 27 Seconds UPS + 1 Extended Run Time Battery Cabinet
        • 24x 12 Volt 7 Amp Hour Batteries
      • 94 Minutes 05 Seconds UPS + 2 Extended Run Time Battery Cabinets
        • 40x 12 Volt 7 Amp Hour Batteries
      • 131 Minutes 43 Seconds UPS + 3 Extended Run Time Battery Cabinets
        • 56x 12 Volt 7 Amp Hour Batteries
      • 169 Minutes 21 Seconds UPS + 4 Extended Run Time Battery Cabinets
        • 72x 12 Volt 7 Amp Hour Batteries
      • 206 Minutes 59 Seconds UPS + 5 Extended Run Time Battery Cabinets
        • 88x 12 Volt 7 Amp Hour Batteries
    • BBP-FE-3000-PSW-ONL-LAB-ABS-7900HT-PCR
    • UL 1778 & CUL, Listed FCC Class A
    • Add A Power Failure Cellular Text/SMS Alert Module
    • Free Shipping/Freight Within The United States Or To U.S. Based Freight Forwarder Specified Location (List U.S. Based Location Specified By Forwarder In Shipping Address For International Orders)

    How The University of Nevada, Reno Keeps Its Lab Running When The Power Fails

    How The University of Nevada, Reno Keeps Its Lab Running When The Power Fails

    How Providence Medical Center Gets Excellent Lab Results Every Time

    How Providence Medical Center Gets Excellent Lab Results Every Time

     How Hematology Oncology Consultants Protects Its Life Saving Refrigerated Drugs

    How Hematology Oncology Consultants Protects Its Life Saving Refrigerated Drugs

    The Uninterruptible Power Supply (UPS) Inverter Capacity XXXX VA / XXXX Watts Determines How Many Watts Can Be Used From The UPS (How Large Of An Electrical Load). This Stays Constant Even If Extra Batteries Are Added. For Example, A 600 Watt UPS Can Run 10x 60 Watt Light Bulbs.

    Extra Batteries Or External Battery Packs/Cabinets Increase Run Time (The Time Electronics Can Be Run On Battery Power). Extra Batteries Do Not Increase The Inverter Capacity (How Many Watts Can Be Used From The UPS). For Example, A 600 Watt UPS Can Still Only Run 10x 60 Watt Light Bulbs, But With Extra Batteries, It Can Run Those Light Bulbs Much Longer.

    Get an estimation of how long your electronics will run on backup battery power with this unit during a power outage. Write down the Power Factor, Number of Batteries, Voltage of Batteries, and Amp Hour Rating from above, then click here to go to our uninterruptible power supply (UPS) backup run time calculator