15 kVA / 10.5 kW Isolated Battery Backup UPS And Power Conditioner For Sensitive Electronics

$ 8,999.99

The 15,000 VA (15 kVA) / 10,500 Watt (10.5 kW) online pure sine wave battery backup uninterruptible power supply (UPS) and 5 tier active power conditioner with surge protection automatically provides defense against power problems. Give your electronics longer life while protecting them from harmful dirty power problems that may otherwise damage or degrade their performance. Much more than a battery in a box, every Battery Backup Power, Inc. system doubles as a power conditioner, actively correcting voltage issues left unresolved by the power company or created by other power hungry electronics in your home or office (laser printers, HVAC systems, refrigeration equipment, etc.). Extend your battery powered run time by adding easy quick connect external battery packs. Cold start functionality allows startup and operation on stored battery power even with no external grid power.

Complete 5 Tier Power Protection System – Surge Protection, Real Time Power Conditioning With Voltage Regulation, Heavy Duty Isolation Transformer, Pure Sine Wave Output, & Always On Double Conversion Backup Power Technology.

Do you need a PDF quote or a custom emergency backup solution? Email us at engineering@batterybackuppower.com


Model Number: Description:
BBP-15000-PSW-ONL UPS With Internal Batteries Only
BBP-15000-PSW-ONL-WEBPWC UPS Plus 1 Extra External Battery Pack
BBP-15000-PSW-ONL-W2EBPWC UPS Plus 2 Extra External Battery Packs
BBP-15000-PSW-ONL-W3EBPWC UPS Plus 3 Extra External Battery Packs
BBP-15000-PSW-ONL-W4EBPWC UPS Plus 4 Extra External Battery Packs
BBP-15000-PSW-ONL-W5EBPWC UPS Plus 5 Extra External Battery Packs

 

  • 15000 VA (15 kVA) / 10500 Watt (10.5 kW)
  • Energy Efficient/High Efficiency UPS Mode >95% Efficiency When Enabled
  • Over 15 Real Time Power Statistics Available From The Front Display
  • Built In Isolation Transformer To Suppress Electrical Noise For Sensitive Devices As Well As Protect Users From Faulty Equipment
  • Tower
  • Pure Sine Wave Clean Output To Operate And Maximize The Life Of Even The Most Sensitive Electronics
  • Online (Double Conversion) - Highest Level Of Protection Available - Battery Power Always Engaged, No Switching Delay
  • Accepts Generator Power (Direct or On Automatic Transfer Switch)
  • Constant Voltage Regulation
  • Constant Frequency Regulation
  • Factory Warranty: 3 Years On Electronics And 1 Year Warranty On Batteries
  • Optional Extended Warranty: 5 Years On Electronics And 2 Year Warranty On Batteries
  • Heavy Duty Industrial Grade For Constant Use
  • For Use With Laboratory Instruments
  • For Use With Sensitive IT Equipment
  • For Use With Audio/Video Equipment
  • 0.7 Power Factor
  • INPUT: Hard Wire 208/220/230/240 Volts Single Phase, 75 Amps Minimum
  • OUTPUT: Hard Wire 120/208/220/230/240 Volts Single Phase | Get Dual Voltage Output By Running The UPS At 208/220/230/240 Volts And Adding A Step Down Transformer (208/220/230/240 Volts Input, 120 Volts Output)
  • Typically Installed On A Branch Circuit 

  • Full Load (10,500 Watts) Estimated Run Time On Battery Power:
    • 09 Minutes On Internal Batteries
      • 40 Batteries, 12 Volts, 7.2 Amp Hours Each
    • 19 Minutes On Internal Batteries + 1 Battery Pack
      • 80 Batteries, 12 Volts, 7.2 Amp Hours Each
    • 29 Minutes On Internal Batteries + 2 Battery Packs
      • 120 Batteries, 12 Volts, 7.2 Amp Hours Each
    • 38 Minutes On Internal Batteries + 3 Battery Packs
      • 160 Batteries, 12 Volts, 7.2 Amp Hours Each
    • 48 Minutes On Internal Batteries + 4 Battery Packs
      • 200 Batteries, 12 Volts, 7.2 Amp Hours Each
    • 58 Minutes On Internal Batteries + 5 Battery Packs
      • 240 Batteries, 12 Volts, 7.2 Amp Hours Each

  • Half Load (5,250 Watts) Estimated Run Time On Battery Power:
    • 19 Minutes On Internal Batteries
      • 40 Batteries, 12 Volts, 7.2 Amp Hours Each
    • 38 Minutes On Internal Batteries + 1 Battery Pack
      • 80 Batteries, 12 Volts, 7.2 Amp Hours Each
    • 58 Minutes On Internal Batteries + 2 Battery Packs
      • 120 Batteries, 12 Volts, 7.2 Amp Hours Each
    • 1 Hour 17 Minutes On Internal Batteries + 3 Battery Packs
      • 160 Batteries, 12 Volts, 7.2 Amp Hours Each
    • 1 Hour 36 Minutes On Internal Batteries + 4 Battery Packs
      • 200 Batteries, 12 Volts, 7.2 Amp Hours Each
    • 1 Hour 56 Minutes On Internal Batteries + 5 Battery Packs
      • 240 Batteries, 12 Volts, 7.2 Amp Hours Each
  • Physical Weight: 632 lbs.
  • Dimensions (Inches): 14" x 34" x 36" (W x D x H) 
  • Operating Temperature: 32°-104° F
  • Operating Humidity: 0 - 95%, Non-Condensing
  • Operating Elevation: 11,482 Feet Maximum
  • Cold Start Capable (Shipped With Cold Start Disabled, Will Enable Automatically After Receiving Power For The First Time After Shipping)
  • Includes UPSMON Plus For Windows Monitoring & Configuration Software: Download Here
  • Add A Power Failure Cellular Text/SMS Alert Module
  • Free Shipping/Freight Within The United States Or To U.S. Based Freight Forwarder Specified Location (List U.S. Based Location Specified By Forwarder In Shipping Address For International Orders)

User Guide:
BBP 6K-20K Double Conversion UPS User And Installation Guide

Spec Sheet/Cut Sheet:
BBP 6K-20K Double Conversion UPS Tower Models

Replacement Batteries:
-Type: 12 Volt 7.2 Amp Hour Batteries
-Make & Model Number: Yuasa NPW36-12 (Sealed Lead Acid) Or Battery Backup Power BBP-LiFePO4-12V-7AH (Lithium Iron Phosphate)
-Dimensions (L x W x H): 151 x 65 x 94 Millimeters | 5.95 x 2.56 x 3.7 Inches

Calculate Estimated Backup Time:


Watch The Video Above To See How Easy It Is To Add Extra Backup Time

How The University of Nevada, Reno Keeps Its Lab Running When The Power Fails

How The University of Nevada, Reno Keeps Its Lab Running When The Power Fails

The Uninterruptible Power Supply (UPS) Inverter Capacity XXXX VA / XXXX Watts Determines How Many Watts Can Be Used From The UPS (How Large Of An Electrical Load). This Stays Constant Even If Extra Batteries Are Added. For Example, A 600 Watt UPS Can Run 10x 60 Watt Light Bulbs.

Extra Batteries Or External Battery Packs/Cabinets Increase Run Time (The Time Electronics Can Be Run On Battery Power). Extra Batteries Do Not Increase The Inverter Capacity (How Many Watts Can Be Used From The UPS). For Example, A 600 Watt UPS Can Still Only Run 10x 60 Watt Light Bulbs, But With Extra Batteries, It Can Run Those Light Bulbs Much Longer.

Get an estimation of how long your electronics will run on backup battery power with this unit during a power outage. Write down the Power Factor, Number of Batteries, Voltage of Batteries, and Amp Hour Rating from above, then click here to go to our uninterruptible power supply (UPS) backup run time calculator