Battery Backup Uninterruptible Power Supply (UPS) And Power Conditioner For Agilent Intuvo 9000 GC, GC/MS, and ALS

$ 8,199.97

The online (double conversion) pure sine wave lab safety battery backup uninterruptible power supply (UPS) and power conditioner with surge protector automatically provides defense against power problems that may impact the performance of the Agilent Intuvo 9000 GC, GC/MS, and ALS. Give your lab instruments longer life while protecting them from harmful dirty power problems that may otherwise damage or degrade their performance. Much more than a battery in a box, every Battery Backup Power, Inc. system doubles as a power conditioner, actively correcting voltage issues left unresolved by the power company or created by other power hungry electronics in your lab environment (laser printers, HVAC systems, refrigeration equipment, etc.).

This is a plug and play system. An existing or electrician pre-wired 208 Volt, NEMA 6-50R (Receptacle) on a 50 amp breaker in your laboratory is all you need. Rolling casters allow you to easily move the entire unit from room to room for use wherever there is a 208 Volt, NEMA 6-50R (Receptacle) available. This system allows for 120 VAC equipment such as computers to be plugged into the top row of outlets on the PDU and 208-240 VAC equipment such as lab instruments and pumps to be plugged into the bottom row of outlets on the PDU. 


User Guides:
-Battery Backup Power 6KVA-10KVA Tower UPS User Guide
-Battery Backup Power 6KVA-10KVA External Battery Pack Tower UPS User Guide
-Battery Backup Power 6KVA-10KVA Tower UPS Parallel System Installation Guide
-Battery Backup Power 6KVA-10KVA Tower UPS Transformer User Guide

Spec Sheet/Cut Sheet:
-BBP 4.5-20KVA Tower DSP Series Specification Sheet.pdf

Complete 5 Tier Power Protection System – Surge Protection, Real Time Power Conditioning With Voltage Regulation, Heavy Duty Isolation Transformer, Pure Sine Wave Output, & Always On Double Conversion Backup Power Technology.

Multiple Backup Time Options:

Model Number: Description (Under Battery Options Drop Down): Approximate Backup Time At Full Load:
BBP-AR-10000-PSW-ONL UPS With Internal Batteries Only (20 Batteries, 12 Volts, 9 Amp Hours Each) 11 Minutes
BBP-AR-10000-PSW-ONL-WEBPWC UPS Plus 1 Extra External Battery Pack (80 Batteries, 12 Volts, 9 Amp Hours Each) 46 Minutes
BBP-AR-10000-PSW-ONL-W2EBPWC UPS Plus 2 Extra External Battery Packs (140 Batteries, 12 Volts, 9 Amp Hours Each) 1 Hour 21 Minutes
BBP-AR-10000-PSW-ONL-W3EBPWC UPS Plus 3 Extra External Battery Packs (200 Batteries, 12 Volts, 9 Amp Hours Each) 1 Hour 56 Minutes
BBP-AR-10000-PSW-ONL-W4EBPWC UPS Plus 4 Extra External Battery Packs (260 Batteries, 12 Volts, 9 Amp Hours Each) 2 Hours 31 Minutes
BBP-AR-10000-PSW-ONL-W5EBPWC UPS Plus 5 Extra External Battery Packs (320 Batteries, 12 Volts, 9 Amp Hours Each) 3 Hours 6 Minutes
  
  • 10000 VA (10 kVA) / 9,000 Watt (9 kW)
  • N+1 And Parallel Operation Up To 40 kVA (4 Units In Series)
  • Energy Efficient/High Efficiency UPS Mode
  • LCD Status Measurements Include Voltage, Frequency, Load Level, Battery Level, Output Current, and Estimated Remaining Backup Time
  • Tower With Casters
  • Pure Sine Wave Clean Output To Operate And Maximize The Life Of Even The Most Sensitive Electronics
  • Online (Double Conversion) - Highest Level Of Protection Available - Battery Power Always Engaged, No Switching Delay (Phase Locked To Input Power Source)
  • Wide Frequency Input Range (44-66 Hz Auto Sensing) Allows For Generator Power To Be Used As A Primary Or Secondary Input Power Source (Using Automatic Transfer Switch Before UPS)
  • Constant Voltage Regulation (±1%)
  • Constant Frequency Regulation (±1 or ±3% Selectable)
  • Factory Warranty: 3 Years On Electronics And 1 Year Warranty On Batteries
  • Optional Extended Warranty: 5 Years On Electronics And 1 Year Warranty On Batteries
  • Digital Signal Processing (DSP) Allows For Greater Reliability Over Older UPS Designs And Superior Electric Noise Filtration
  • >0.99 Input Power Factor / 0.9 Output Power Factor (Line Mode) / High Efficiency Mode For Superior Efficiency And Power Savings
  • INPUT OPTIONS: Hardwire Terminal Block, NEMA 6-50P (Plug), NEMA 14-50P (Plug), Or Hubbell CS8265C (Plug)
    • 208, 220, 230, or 240 Volts Single Phase, 50 Amps Minimum
  • OUTPUT OPTIONS: Hardwire Terminal Block, NEMA 5-15R (Receptacle), NEMA 5-20R (Receptacle), NEMA L5-30R (Receptacle), NEMA 6-15R (Receptacle), NEMA 6-20R (Receptacle), NEMA L6-15R (Receptacle), NEMA L6-20R (Receptacle), NEMA L6-30R (Receptacle), NEMA 14-30R (Receptacle), NEMA 6-50R (Receptacle), NEMA 14-50R (Receptacle), Custom (Contact Us For Custom Or Unlisted Options), Or Dual Voltage Multiple Receptacle Box
    • 120, 120/240, 120/208, 208, 220, 230, or 240 Volts Single Phase
    • UPS Weight (Excluding Optional External Battery Packs): 327.8 lbs.
    • Dimensions (Inches): 11.4 X 34.7 X 25.4 (W x H x D)
    • Operating Temperature: 32°-104° F
    • Operating Humidity: 20%~95%, Non-Condensing
    • Operating Elevation: 3,280 Feet Without De-Rating 
    • Cold Start Capable (Shipped With Cold Start Disabled, Will Enable Automatically After Receiving Power For The First Time After Shipping)
    • cTUVus, cULus, and FCC Certified
    • Includes Software For Windows Monitoring & Configuration 

    Replacement Batteries:
    -Leoch DJW12-9.0 (Lead Acid), Leoch LP12-9.0 (Lead Acid)Betta Batteries 6-HCNFJ-7.2 (Lead Crystal), Or Battery Backup Power BBP-LIFEPO4-HDR-12V-7.2AH (Lithium Iron Phosphate)

    Do you need a PDF quote or a custom emergency backup solution? Email us at engineering@batterybackuppower.com.